FuSa dossier · upstream HARA
Upstream HARA
The vehicle hazard analysis stays with the upstream item owner. This repository supplies platform evidence. It does not fill S / E / C here, and it does not write a drill ASIL into a safety goal.
Who writes, who uses
| Upstream HARA | This item | |
|---|---|---|
| Role | Vehicle / function item | SEooC (ISO 26262-10) |
| Owner | OEM or the functional-safety lead | This repository |
| Work product | Situations, hazardous events, S/E/C, safety goals, ASIL, safe state, FTTI | Platform requirements, software safety requirements, detection time, isolation |
| Now | Another volume, assumption A-06 | SG-01…05 have an intent; ASIL stays TBD |
Handed to this item
| Field | Use |
|---|---|
| Safety-goal statement | Align or extend an SG |
| ASIL | Written onto the SG, then inherited or decomposed along PR → FSR → SR |
| Safe state | Where degrade, restart, or a rejected transition must land |
| FTTI | The ceiling for detection time, compared with detection time |
Until that allocation arrives, detection time is compared only with the host SIL budget. That column is an engineering gate, not an FTTI, and not a board limit (assumption A-07).
Handed back
The integrator cites these in the vehicle safety case. A page drill is not a HARA conclusion.
| Handed back | Where |
|---|---|
| PR-01…05 and the FSRs | Requirements |
| SG → SR → L1/L3 | Trace |
| Isolation scenarios | Isolation |
| Detection-time snapshot | Detection time |
Random hardware faults do not come from the HARA page. They go through hardware.