FuSa dossier · hardware FMEDA
Hardware
Random-hardware metrics belong to the hardware element. The SoC safety manual and the board are both inputs. This repository does not pick a production SoC, does not copy manual numbers, and does not fold software detection time into PMHF.
Who writes, who uses
| Hardware FMEDA | This item | |
|---|---|---|
| Role | Hardware element / safety manual | Software SEooC |
| Owner | Hardware safety lead; the SoC vendor supplies the manual | This repository |
| Hands over | λ, DC, SPFM, LFM, PMHF, hardware safety mechanisms | Alive/Deadline, process restart, legal transitions, a local event ring |
| Now | Manual id still blank | Software evidence is on the trace |
Where it meets this item
| Direction | Content | Where |
|---|---|---|
| Hardware / OS → this item | Clock, process, and storage primitives are available | Assumption A-01. SIL approximates them with host POSIX. The board is measured separately |
| This item → integrator | Whether software mechanisms detect the fault inside the budget | Detection time, isolation |
| Hardware FMEDA → vehicle safety case | Whether random hardware faults meet the target ASIL bar | The safety manual. The metrics page only shows the formulas |
Software mechanisms prove this item's requirements. If their diagnostic coverage enters a hardware FMEDA, the hardware analysis lists it on its own. This page does not add the two sides. Upstream HARA supplies the safety goal and FTTI, not a FIT number. See upstream HARA.
Support this item needs
Properties first. Lockstep, ECC, a clock monitor, a watchdog, dual supply, and a voltage monitor are mechanisms. They wait for a safety manual. Until an ASIL is allocated, this item does not claim a level. Bars: ASIL B / C / D need SPFM ≥ 90% / 97% / 99%, LFM ≥ 60% / 80% / 90%, PMHF < 100 / 100 / 10 FIT.
| Property | Serves | Mechanism |
|---|---|---|
| A supervised monotonic clock | SG-02 | Waiting for the manual |
| Process control and reset | SG-01 | Waiting for the manual |
| Retentive storage | SG-04 | Waiting for the manual |
| Power loss can reach a safe state | Not yet allocated | Waiting for the manual |
FTA and cut sets are not on this page. They wait until a safety goal has an ASIL and a manual is chosen. The PMHF on the metrics page does not compute cut sets.
Project hardware safety manual
After the hardware is chosen, only this table is filled. The manual body is not copied into the repository.
| Project | SoC / hardware | Manual id / revision | Status |
|---|---|---|---|
| — | — | — | Not bound |