中文

FuSa dossier · safety goals

Safety goals

Candidate goals for the platform. The ASIL column stays TBD until upstream allocates one. Identifiers line up with the requirements and the trace.

SG-01SG-02SG-03SG-04SG-05

SGIntentASILSREvidence
SG-01After a critical process exits, the platform can detect it and restart or degrade, without losing supervision in silenceTBDSR-01.1…01.4EM · SIL-EM-02 · ISO-EM-01
SG-02Alive / Deadline misses are detected inside the configured window and health returns after recovery; a bypass can keep running while a fault is isolatedTBDSR-02.1…02.5PHM · SIL-03 · ISO-PHM-01
SG-03Illegal function-group transitions are rejected, and a health fault can be notified to SMTBDSR-03.1…03.5SM · ISO-SM-01
SG-04Platform fault events are recorded by Collector in a local ring, for later analysisTBDSR-04.1…04.4COLL
SG-05A production profile can turn the debug path off, and the main chain does not depend on host toolsTBDSR-05.1…05.2open · SIL-T4

Coverage

SGL1L3 fusaIsolationNote
SG-01yesyesyesRelaunch measured; SIL budget ≤ 50 ms
SG-02yesyesyesDetect and recover measured
SG-03yesSIL-SM-01yes
SG-04COLL-X*with SIL-SM-01yesShared NDJSON store
SG-05L2SIL-T4—GF_FUSA_T4=1

Not in this stage