中文

Automotive SPICE 4.0 · Process trace

SWE.1 · Software requirements

This stands at 0. The next step is a review record. The trace already here: Software requirements

Back to the assessment · Register

0 1 2 3 4 5

0 · Now

  1. The software requirements already have a reading page. A requirement identifier points at an entry.
  2. There is no review record: no configuration identifier of the reviewed version, no reviewer independent of the author, no review result, and no finding.
  3. The purpose of this level is not achieved. The level is 0.

Review record

Review objectConfiguration identifierReviewerReview resultFindingIdentifier of the record
No record yet

This table has no record yet. The next section is how to establish it. Register this table

1 · Next

  1. Identify the {'html': '<a href="../fusa/requirements.html#sr-03">SR-03</a>'} under review and its configuration identifier. The review applies to that identifier.
  2. The reviewer is independent of the author.
  3. The review result is Accepted, Accepted with comments, or Rejected. Rejected and Accepted with comments record a finding and point at the affected entry.
  4. After a finding is closed, review again. The new result is appended on the same review record. The earlier result stays.
  5. The review record and the reviewed version share one configuration identifier.

Review record

Review objectConfiguration identifierReviewerReview resultFindingIdentifier of the record
No record yet

This table has no record yet. The steps in this section say how to fill it. Register this table

2

  1. Establish the review plan, complete one tracking record, then place Accepted and Accepted-with-comments entries on the baseline. All three records are required.
  2. The review plan names the configuration identifier, the reviewer, and where the review record will be stored. A date is entered when it is set.
  3. The tracking record states whether this pass is not reviewed or reviewed, and the review result.
  4. Accepted and Accepted-with-comments entries go on the baseline, with the baseline identifier. Findings on Accepted with comments stay open.

Review plan

Review objectConfiguration identifierReviewerIdentifier of the record
No record yet

This table has no record yet. The steps in this section say how to fill it. Register this table

Tracking record

Configuration identifierReview statusReview result
No record yet

This table has no record yet. The steps in this section say how to fill it. Register this table

Baseline

Requirement identifierReview resultBaseline identifier
No record yet

This table has no record yet. The steps in this section say how to fill it. Register this table

3

  1. Write the procedure for the software-requirements review, one entry at a time, including the completion criterion.
  2. For each entry, write how this item implements it.
  3. A nonconformity is its own row. A change to the procedure or to the implementation is another row, with its configuration identifier.
  4. The procedure and the conformity comparison share one configuration identifier.

Conformity comparison

Procedure entryImplementation on this itemConformityIdentifier of the comparison
No record yet

This table has no record yet. The steps in this section say how to fill it. Register this table

4

  1. Measurement comes from MAN.6. MAN.6 is outside this pass, so the table below stays blank.
  2. Before the work, write the expected result of the software-requirements review.
  3. After the work, write the actual result.
  4. When the result drifts, write the adjustment and its configuration identifier.
  5. A product-gate result is not entered in this table.

Process measurement

Expected resultActual resultDriftIdentifier of the adjustment
————

The cells stay blank. Process measurement comes from MAN.6, which is outside this pass. Register this table

5

  1. Take one drift from the level-4 process measurement.
  2. Change the procedure entry that corresponds to that drift.
  3. Name the measurement the change rests on.
  4. The changed procedure stays on the baseline and cites that measurement.

Procedure change

Procedure entry changedMeasurementChangeIdentifier of the change
————

The cells stay blank. Level 4 has no measurement, so this level has no record to rest on. Register this table